Search results

Search for "high-content imaging" in Full Text gives 3 result(s) in Beilstein Journal of Organic Chemistry.

Automated high-content imaging for cellular uptake, from the Schmuck cation to the latest cyclic oligochalcogenides

  • Rémi Martinent,
  • Javier López-Andarias,
  • Dimitri Moreau,
  • Yangyang Cheng,
  • Naomi Sakai and
  • Stefan Matile

Beilstein J. Org. Chem. 2020, 16, 2007–2016, doi:10.3762/bjoc.16.167

Graphical Abstract
  • results can be obtained from dose–response curves of the targeted delivery to selected cells and the cytotoxicity in the same experiment, even with poorly optimized cellular systems. Keywords: automation; cell-penetrating peptides; cellular uptake; cytosolic delivery; cytotoxicity; high-content imaging
  • ). While the error from the whole-cell analyses with HGM cells is not catastrophic (r2 = 0.977 vs r2 = 0.983), these results show that automated high-content imaging is absolutely necessary with less optimized systems (r2 = 0.626 vs r2 = 0.816). The difference between the optimized HGM cells and the
PDF
Album
Supp Info
Full Research Paper
Published 14 Aug 2020

Targeted photoswitchable imaging of intracellular glutathione by a photochromic glycosheet sensor

  • Xianzhi Chai,
  • Hai-Hao Han,
  • Yi Zang,
  • Jia Li,
  • Xiao-Peng He,
  • Junji Zhang and
  • He Tian

Beilstein J. Org. Chem. 2019, 15, 2380–2389, doi:10.3762/bjoc.15.230

Graphical Abstract
  • step, HepG2 and HeLa cells were simultaneously incubated with Glyco-DTE and then imaged with an Operetta high content imaging system. As shown in Figure 4A, a bright fluorescence signal was detected in HepG2 cells but almost no fluorescence signal was observed in HeLa cells. This suggested a good
PDF
Album
Supp Info
Full Research Paper
Published 07 Oct 2019

Chemical–biological characterization of a cruzain inhibitor reveals a second target and a mammalian off-target

  • Jonathan W. Choy,
  • Clifford Bryant,
  • Claudia M. Calvet,
  • Patricia S. Doyle,
  • Shamila S. Gunatilleke,
  • Siegfried S. F. Leung,
  • Kenny K. H. Ang,
  • Steven Chen,
  • Jiri Gut,
  • Juan A. Oses-Prieto,
  • Jonathan B. Johnston,
  • Michelle R. Arkin,
  • Alma L. Burlingame,
  • Jack Taunton,
  • Matthew P. Jacobson,
  • James M. McKerrow,
  • Larissa M. Podust and
  • Adam R. Renslo

Beilstein J. Org. Chem. 2013, 9, 15–25, doi:10.3762/bjoc.9.3

Graphical Abstract
  • compound concentrations required to reduce parasite numbers in C2C12 host cells by 90% as compared to untreated controls, as determined by using a high-content imaging-based screening (HCS) approach [33][40]. This high-throughput assay provides a rapid measure of the initial acute effects of test compound
PDF
Album
Supp Info
Full Research Paper
Published 04 Jan 2013
Other Beilstein-Institut Open Science Activities